Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
20049 | THE ELECTRIC TACHOMETER CORP. |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.500 INCHES |
CWLN | TERMINAL DESIGN | LINKED NONFEEDTHRU |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | QQ-B728,CLASS B FED SPEC SINGLE MATERIAL RESPONSE TERMINALS |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 2 SINGLE |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.500 INCHES |
ABGS | BASE THICKNESS | 0.312 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
CSCR | TERMINAL CONNECTING LINK TYPE | 1 SINGLE |
MARK | SPECIAL MARKINGS | 1,2 |
ABGQ | BOARD OVERALL HEIGHT | 0.594 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.438 INCHES |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-M-14,TYPE MAI-60 MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.250 INCHES |
AMPS | CURRENT RATING IN AMPS | 20.0 |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.375 INCHES |
ABGP | BOARD OVERALL WIDTH | 0.875 INCHES |
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 2 SINGLE |
ABGN | BOARD OVERALL LENGTH | 1.625 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.188 INCHES |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1.5 |
MATT | MATERIAL | COPPER ALLOY 670 TERMINALS |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
AAQX | MOUNTING SLOT WIDTH | 0.180 INCHES |
CRNL | NONFEEDTHRU TERMINAL TYPE | 600 SINGLE |
AAQW | MOUNTING SLOT LENGTH | 0.210 INCHES |
MATT | MATERIAL | PLASTIC POLYESTER BOARD AND GLASS FIBER BOARD |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOT |
AAQL | BODY STYLE | BARRIER TYPE |